Hazardous Location Valves [27 Series]
2771B5002Z
VALVE TYPE | Hazardous Location |
VALVE FUNCTION | 2/2 Single Solenoid |
SERIES | 27 |
CONSTRUCTION | Poppet |
MOUNTING | Inline |
THREAD TYPE | NPT |
ACTUATION | Electrical |
DEFAULT POSITION | Normally Closed |
VOLTAGE | 120 VAC |
INLET SIZE | 3/4" |
OUTLET SIZE | 3/4" |
EXHAUST SIZE | N/A |
BODY SIZE | 3/4" |
LENGTH | 4.45 in (113 mm) |
WIDTH | 3.15 in (80 mm) |
HEIGHT | 9.0 in (229 mm) |
WEIGHT | 3.6 lb (1.6 kg) |
PORTS 1-2 FLOW | 9 Cv (8856 Nl/min) |
PORTS 1-4 FLOW | N/A |
PORTS 2-3 FLOW | N/A |
PORTS 4-3 FLOW | N/A |
AMBIENT TEMPERATURE RANGE | 40 to 140 F (4 to 60 C) |
MEDIA TEMPERATURE RANGE | 40 to 175 F (4 to 80 C) |
FLOW MEDIA | Filtered air |
OPERATING PRESSURE MAX | 150 psi (10 bar) |
VALVE BODY MATERIAL | Cast Aluminum |
POPPET/SPOOL MATERIAL | Acetal and Stainless Steel |
SEAL MATERIAL | Buna-N |
CSA/UL CERTIFICATION | Yes |
FM APPROVED | Yes |